ranowatsProfessional cold storage installationhow much

release time: 2024-04-17 00:02:08

With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?Compression refrigerator is commonly used. It is mainly composed of compressor, condenser,ranowatsFruit and vegetable cold storage, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.ranowats,It takes hours after the installation of the controlled atmosphere warehouse to deposit the goods, so as to quickly meet the temperature required by the goods and ensure that the controlled atmosphere warehouse equipment can operate normally.Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.Greenville,More and more people begin to build cold storage, and most people choose to use cold storage for cold storage construction. Why? Why do people choose cold storage for construction? What are the advantages of cold storage? The following is a detailed introduction.Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, etc. and the welded junction shall be moisture-proof and treated according to the drawing requirements.


ranowatsProfessional cold storage installationhow much



Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.Establish a perfect computer network to realize the scientization of refrigeration supply chain distribution and traceability. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.Fair price,The cold storage shall be regularly overhauled and maintained, so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Relative humidity maintenance of quick-frozen warehouse: humidification of quick-frozen warehouse is very important, from centrifugal humidification to high-pressure micro fog humidification, gas-water mixed humidification, to the current ultrasonic humidifier. The utility model has the advantages of small particles, uniform humidification, no freezing and blocking, and no dirty blocking. The air conditioning humidifier we produce is specially designed for all kinds of vegetable and fruit quick freezing warehouses, which is essentially different from other humidifiers in the market: fully closed circulation, that is, take the gas in the warehouse, return to the warehouse through the humidifier and isolate it from the outside air.


ranowatsProfessional cold storage installationhow much



- precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plateDuring the use of cold storage, which will seriously reduce the local thermal insulation performance of the storage body.If the refrigerator has been used for more than months, or the high / low voltage switch often fails, or the refrigeration capacity is reduced, please arrange staff to clean the condenser. If the ultra-thin light box is repaired according to the above instructions for many times, and the refrigerator fault still sounds for a long time,ranowatsInstallation of low temperature freezer, please ask the maintenance personnel of the refrigerator to repair it.Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.ranowats,Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.In order to prevent damage to the cold storage,ranowatsFruit and vegetable cold storage installation company, it is necessary to lay some foam on the floor of the cold storage tank. - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

If you think this entry needs to be improved, please edit

Previous TanobjegVehicle mounted hydraulic platformStable price    Next StrugaPlastic floorRecommend Consultation