Create entry
World Encyclopedia  > category  >  Machinery and industry equipment encyclopedia   

AugsburgAluminum alloy lifting platformSurface category

release time: 2024-04-25 16:47:40

The frequency conversion system circuit of the construction elevator is mainly composed of two parts: the main circuit and the circuit. The main circuit is mainly composed of a construction lifting cargo elevator (hereinafter referred to as the lifting cargo elevator) driven by a more complex rectifier. Before installation, and the two are connected. Starting from adjusting the driving mechanism, power on the suspension cage to lift it m above the ground or detach it from the ground buffer spring (or support). The adjustment and sequence are as follows: . Use a special wrench to rotate the lower double (single) pendulum eccentric shaft to adjust the eccentricity to ensure that the installation plate surface of the driving mechanism is perpendicular to the horizontal plane, and ensure that the upper and lower pendulum wheels evenly guide the rails at the same time. Use your hand to move each wheel body and check if it evenly presses the rails; . Use a special wrench to rotate the eccentric shaft of the gear rack back pressure wheel to adjust the side clearance during gear rack meshing. When adjusting, use a feeler gauge to measure the side clearance to .; Between .mm, each pressing wheel should evenly press on the back of the rack. Move each wheel body by hand to check if it evenly presses against the tooth back. Similarly, adjust the guide rollers on both sides of the guide rail. The adjustment key is to adjust the guide wheel on one side of the guide rail to lightly press it onto the guide rail. When moving the wheel body by hand, it should be possible to rotate but there should be obvious obstruction; The roller on the other side should maintain a clearance of .-. ram with the guide rail; . Adjust the lifting cage according to the above and sequence. If the driving mechanism and the lifting cage are integrated into the lifting cargo elevator, the lifting cage should be adjusted according to the and sequence of adjusting the driving mechanism. Conduct a visual inspection of the operation of each roller, and use the lead pressing method and coloring method to check the meshing of the gear pair; Fine tune pairs of unsatisfactory parts. The key point is to carefully adjust the meshing status of the gear pair: when the spots shown in appear on the surface of the gear rack, it indicates that the driving mechanism is tilted towards the side of the guide rail. At this time, the lower swing wheel (single or double wheel) should be adjusted to move the lower part of the driving mechanism towards the direction of the guide rail until the area of the spots reaches more than % of the surface of the gear rack. The smaller the area, the easier it is to damage the gears and racks.Regularly check the connection of each part and tighten it if there is any looseness. The tightness of the body connecting bolts should be checked when the body is under pressure (the rotating arm can be used to cause compression)Augsburg,Thermal aging stress relief is generally suitable for small workpieces, while the lifting foundation structure has a large volume and does not have a large enough annealing furnace. Using natural aging takes one year and the production cycle is too long, so neither of these two methods is feasible. After research and understanding by the manufacturer, it was found that selecting appropriate support points for large welded structural components can perform vibration aging stress relief. Therefore, the manufacturer has decided to use vibration aging for stress relief of the platform lifting foundation. Long term promotion of downgrading manufacturers, old brands, price advantages, and guaranteed quality!  ?? The supervision unit shall effectively fulfill its safety responsibilities, and if any potential production safety accidents are found,AugsburgPrice of guide rail type lifting platform, it shall require the installation unit and the user unit to rectify within a specified period of time. If the installation unit and the user unit refuse to rectify, they shall promptly report to the construction unitSpisska Nova Ves,Quarterly maintenance: Check the items checked each monthEvery customer pays attention to the price of elevators, so how does the manufacturer calculate the price of elevators? In general, the manufacturer calculates the price of the elevator for customers based on the actual size, height, as the different materials used, material brands, and production processes result in different prices for elevators Customers can consider the cost-effectiveness of elevators more when purchasing, with the principle of getting what they pay for. Safety hazard elimination plan for lifting cargo elevators: When there is a malfunction or abnormal situation in the lifting cargo elevator, it should be immediately stopped from use. After eliminating the malfunction and accident hazards, it can be put back into useUse a feeler gauge to check the wear condition of the worm gear of the worm gear reducer. Please refer to the instruction manual for specific requirements


AugsburgAluminum alloy lifting platformSurface category



Manganese steel is generally used as the primary profile for warehouse cargo elevators. In order to achieve better anti-corrosion effect, a layer of rust resistant primer is usually applied, Ruilong hydraulic press will explain the role of rust resistant primer.Applicable environment: Indoor or outdoor Applicable temperature: Safety device Safety rocker: When the equipment is running and rising, the rocker will automatically prevent wheelchair platform.The lifting stage can provide real-time information on the operation of the entire vehicle, avoiding relying solely on the experience of operators to coordinate with each other, and improving the reliability and safety of the system. The definition of safety zone is very important because the lifting stage has a large range of movements, and it must be accurately calculated. The lifting stage has two structurally separate systems, the ground turntable and the high-altitude work bar. However for various movements on the vehicle, it is also an interconnected system, which needs to consider the priority of operation, system redundancy, and safety assurance of actions.DiscountOn the contrary, it should be adjusted in the opposite direction; When the meshing backlash of the gear pair is greater than .mm, loosen the connecting nut of the eccentric shaft of the guide roller and the tooth back pressure wheel as shown in adjust the tooth back pressure wheel to press towards the back plane of the gear rack until the backlash reaches a reasonable range. Otherwise, it should be adjusted in the opposite direction. At this point, the guide roller should be loosened for o and then adjusted according to the adjustment of the guide roller.Clean and inspect the crown wheel frame assembly, correct or replace with new partsThe lifting stage is a high-altitude operation equipment,AugsburgMobile lifting platform,AugsburgGuide rail platform lifting platform, and prolonged use can cause loose connections between some components. So in order to ensure the personal safety of construction workers, it is necessary to regularly inspect the lifting stage and tighten any loose components. The lifting stage is a high-altitude operation equipment, and prolonged use can cause loose connections between some components. So in order to ensure the personal safety of construction workers, it is necessary to regularly inspect the lifting stage and tighten any loose components. The interference and hazard analysis of the frequency conversion speed regulation construction elevator circuit is becoming increasingly widespread in the development of technology today. Variable frequency speed regulation has the characteristics of stable start and stop process, reducing mechanical shock, increasing the comfort of passengers, and improving the service life. At the same time, it can also change the speed of power supply frequency regulation, save electric energy, and improve work efficiency. However, there will be interference in the use of variable frequency speed regulation system, which will often cause safety accidents of construction elevator.


AugsburgAluminum alloy lifting platformSurface category



On the contrary, it should be adjusted in the opposite direction; When the meshing backlash of the gear pair is greater than .mm, adjust the tooth back pressure wheel to press towards the back plane of the gear rack until the backlash reaches a reasonable range. Otherwise, it should be adjusted in the opposite direction. At this point, the guide roller should be loosened for o and then adjusted according to the adjustment of the guide roller.Service first,The cleaning oil for the hydraulic system must use hydraulic oil of the same brand as the system used, with an oil temperature between and ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more. After each cleaning, fully drain the system while the oil is hot.According to GB/T-, when one of the following situations occurs in the curve related to the aging frequency, it can be determined that the area covered by the effective zone of the vibration mode at that frequency has reached the aging effect: the curve rises and flattens; The curve rises, then falls, and then flattens; The resonance frequency of the a-n curve after vibration is lower than that before vibration; The bandwidth of the a-n curve after vibration narrows compared to before vibration; The resonance peak of the a-n curve after vibration exhibits fission phenomenon; The curve flattens out after descent.A non scissor type hydraulic lifting mechanical equipment used for transporting goods between floors of industrial factories, restaurants, and restaurants on the second and third floors. Professional elevator manufacturers are safe, environmentally friendly and economical! Our products are exported to foreign countries and highly trustedAugsburg,Check if the orientation of the upper and lower limit blocks on the guide rail frame is correctCheck the safety interlocking equipment of the first cut door of the hanging cageWhen disassembling the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts, it is necessary to avoid dust during the system oil passage. The disassembled parts must be thoroughly cleaned before opening. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap. After loosening the tank cap, materials that do not remove fiber impurities and specialized hammers with rubber attached to the surface should be selected. Hydraulic components and hydraulic hoses should be carefully cleaned, dried with high-pressure air and then assembled. Choose a well packaged filter element (the inner packaging is damaged, although the filter element is intact, it may also be unclean). When changing the oil, clean the filter at the same time. Before installing the filter element, carefully clean the bottom dirt inside the filter housing with materials.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms