Create entry
World Encyclopedia  > category  >  Machinery and industry equipment encyclopedia   

Tony kapanStandard for power frequency withstand voltage test of dry type transformerHow to speed up marketization and eliminate backward production capacity

release time: 2024-02-22 09:57:21

In relay protection dry-type transformer, the disconnection of the fault point is related to each other. In a word, if there is any problem at a certain point, it will affect the whole power circuitThe method and whole process of taking oil sample of power transformer are as follows:Tony kapan,Hand touch method for transformer inspectionSound insulation treatment of main engine room the key to sound insulation treatment of dry-type transformer room is to start from three levels: window, ventilation and air exchange port and road surface, and apply sound insulation window, silencing cylinder, floating concrete floor damping pad and other sound insulation and noise reduction commodities to achieve sound insulation effect.Takamatsu,Power transformer manufacturerFor the leakage that has already occurred, find the leakage point first, which can not be ignored. For the position with serious leakage shovel or sharp punch can be selected. The leakage point can be riveted with special tools for metal materials. After manipulating the leakage, the treatment surface shall be cleaned and tidy. Polymer composite materials are mostly selected for dry consolidation. After dry consolidation,Tony kapanOn load voltage regulating power transformer, the goal of long-term treatment of leakage can be achieved.Power transformer manufacturer


Tony kapanStandard for power frequency withstand voltage test of dry type transformerHow to speed up marketization and eliminate backward production capacity



There are also many problems to pay attention to in the preventive measures and process of dry-type transformer damping. What are the key effects and functions of dry-type transformer damping and the corresponding preventive measures? Let's master and consult in detail with the small editor of the dry-type transformer manufacturer.Hand touch method for transformer inspectionThe representative mode of connection group of dry-type transformer is: English capital letters indicate the wiring on the primary side (or primary side),Tony kapanPower transformer model, and English letters indicate the wiring on the secondary side (or secondary side). Y (or y) is star wiring, and D (or D) is triangular wiring.reform,The tail end of the high-voltage winding head and the middle tap are made of copper inserts and embedded parts, with good strength and stiffness, which is conducive to adjusting the data and has a unique and neat style.The capacity and working voltage are different. The dry-type transformer is generally suitable for distribution equipment. The capacity is generally below kVA and the working voltage is below KV, which also ensures the rated voltage of kV; Oil immersed transformers are generally suitable for distribution equipment.Falling foreign matters and piercing


Tony kapanStandard for power frequency withstand voltage test of dry type transformerHow to speed up marketization and eliminate backward production capacity



During no-load test run, the transformer shall be connected with the working voltage from the switching power supply side,Gradually, high-frequency vibration damping mechanical equipment, such as low-frequency vibration damping platform, is installed at the bottom of the dry-type transformer, which can reduce the downward dispersion of the vibration of the dry-type transformer. Then replace the connection between the dry-type transformer and the surrounding engineering buildings, roads, or use elastic yellow shock absorption mechanical equipment to prevent the vibration from spreading according to the rigid connection. If possible the dry-type transformer room can also be soundproofed and decorated, and sound-absorbing plates and silencing shutters can be used to improve the soundproofing capacity of the dry-type transformer room.Power saving analysis of transformerOperation of oil immersed transformerTony kapan,If the volume of power transformer is too small, the transformer will be overloaded for a long time and it is easy to destroy machinery and equipment. Therefore,Tony kapan1250KW dry type transformer, the rated capacity of the transformer should be selected according to the power consumption, which is not suitable for too large or too small.In order to better reduce the probability of short-circuit fault of relay protection dry-type transformer, prevention and key are & ldquo; Prevention and Manipulation & rdquo; Is dominant.When the full load test is carried out and everything is normal, the load can be connected.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms