release time: 2024-04-18 06:17:12

Whether there is dirt on the condenser and poor heat dissipation will lead to too high condensation pressure of the refrigerator. In order to protect the compressor, the machine stops running under the action of the pressure controller. When the heat dissipation is good, press the black reset button on the pressure controller, and the machine can automatically resume operation.At ordinary times, users should check the sealing degree of the gap of the cold storage,After years of service, the refrigeration oil inside the compressor should be replaced. The oil, copper, iron and impurities caused by wear are mixed in the refrigeration system which thickens the refrigeration oil, deteriorates the fluidity and performance reduces the effect, takes a long time, increases the burden on the compressor, and the current will increase relatively compared with the new machine, which is a bad phenomenon.During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.SaintLaurent,Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.


negotiationProfessional cold storage company installationWhat are the types of



Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications, and corresponding protection measures shall be taken for the installed equipment.The valve shall be installed as close as possible to the cooling fan. The solenoid valve shall be installed horizontally, the valve body shall be vertical, and pay attention to the liquid outlet direction.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity production process, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.Welcome calls ,negotiationFruit and vegetable cold storage,During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, and there shall be no joint in the middle. The junction of polyurethane insulation board, top plate and ground shall be made into fillet arc for transition which can well meet the health needs.


negotiationProfessional cold storage company installationWhat are the types of



Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications, and corresponding protection measures shall be taken for the installed equipment.build,The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.The installation of refrigeration pipeline requires that the diameter of copper pipe shall be selected in strict accordance with the interface of compressor suction and exhaust valve. When the separation between condenser and compressor exceeds M, the pipeline diameter shall be increased.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.negotiation,Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places,negotiationInstallation cost of cold storage project, such as brine ice making and cold storage with constant temperature requirements.For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick),negotiationInstallation design of medical cold storage, and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.Cold storage design segmentation: several different partitions shall be reasonably planned and divided according to purpose and temperature. For example: processing room, quick freezing room, refrigeration room, channel, unloading platform, etc.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms