New CityMobile electric elevatorAdjust industry process parameters

release time: 2024-03-29 17:26:51

Horizontal lead screw mechanical electricityThe wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.New City,We have all purchased the aluminum alloy electric elevator equipment, hospitals, airports, and large parking lots also wear this equipment,Steel wire ropes, pulleys and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T; Maintenance, wear, deformation, and corrosion of steel wire ropesBoulogne byangou,Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance the protective measures taken should comply with the specification requirements.Later, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.


New CityMobile electric elevatorAdjust industry process parameters



When the door is closed,New City2 meter electric lifting platform, except for the gap between the lower part of the door that should not exceed mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table of GB -.The body in the lateral adjustment device of the driving plate should ensure a compressed state, so that the gear has a certain radial constraint, and ensure that the gear and rack always mesh well throughout the entire operation.News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years,New CityElectric lifting platform 2 meters, the products of electric lifting platform vehicles have been continuously improved,New CityElectric high-altitude elevator, and various new technologies and materials have emerged, making the further development of lifting platform vehicles possible.Inspection environment,Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.The scaffolding of the parking platform should be laid tightly and firmly.


New CityMobile electric elevatorAdjust industry process parameters



The scaffolding of the parking platform should be laid tightly and firmly.Where is good, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed mm.Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.New City,Model Example: Hanging Cage Specification: LABSC/TDx Type I: ~ Type II: ~ Type V: ~ Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x. (kN).The quality of the standard section should comply with the product manual and specification requirements.Mechanical devices controlled by cage movement should not be used to open or close the landing door.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms