Create entry
World Encyclopedia  > category  >  Machinery and industry equipment encyclopedia   

CampelGrenobleCapacity effectiveness

release time: 2024-03-28 06:57:31

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, and concrete strength report.Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends,CampelRimini, it can automatically cut off the oil circuit and stop descentCampel,Only after the operation of professional personnel can the suspension cage movement be restored.When the foundation is set on the roof or floor structure,Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB&flash; The rotation of the SB motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.Double layer steel mesh: The diameter of the steel bars is mm, with a spacing of mm.


CampelGrenobleCapacity effectiveness



The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit and verified by experts.The cargo is .m.Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.Product survey,CampelLa Rochelle ,Implementing multiple shifts of homework should fill in and submit records according to regulations.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.Setting requirements: For construction electric elevators with foundations installed on roof slabs,CampelGu Ye, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.


CampelGrenobleCapacity effectiveness



Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.Installation material list,The quality of the standard section should comply with the product manual and specification requirements.Is there a relevant rule requirement for the cleanliness of hydraulic stations?Implementing multiple shifts of homework should fill in and submit records according to regulations.Campel,When the door is closed, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table of GB -.To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling and lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference, ensuring the safety of the cast members.Construction electric elevators outside the lightning protection range


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms