In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state the elevator should immediately stop on the floor without opening the door, and automatically open the elevator door if it is in the upward direction.When the normal power supply is cut off return to the first floor station, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.Pwotsk,There are many similar situations in daily life, such as forcefully opening the door inside the car, causing the circuit to disconnect and forcing the elevator to stop, resulting in people being trapped. For example, if the elevator frequently enters and exits during decoration and falls into the crack of the door, the elevator hall door may not be tightly closed, and after several consecutive doors are opened and closed, the elevator will stop. Professional quality assurance for home elevator manufacturers. Discount activities are underway, and new and old customers are welcome to come for consultationMeasurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed,PwotskResidential use of indoor elevators in duplex buildings, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Antofagasta,Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling it will cause wear and tear on the mechanical components of the elevator, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, then consider the non-standard design of the elevator.


PwotskVertical obstacle free lifting platformWhat is the role of description



Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Slide elevators are installed inside buildings and are often used parallel to buildings and sidewalksThe treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Application process,Cleaning and cleaning of elevator car guide shoes. As is well known, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyThe effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.


PwotskVertical obstacle free lifting platformWhat is the role of description



Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.Standard requirements,The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesWhen accidentally trapped in an elevator, press the alarm bell inside the elevator, and call the elevator emergency rescue phone or community property phone for help. Do not open doors or mess with buttons, and patiently wait for rescue.If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Pwotsk,The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side,PwotskStage style lifting platform, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform,PwotskAluminum alloy high-altitude lifting platform, attention should be paid to the length of the pit or the opening of the floor slab which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.The front room of the fire elevator is equipped with indoor fire hydrants.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms