BlanickInstallation cost of fruit fresh-keeping cold storageSpecific management requirements analysis

release time: 2023-03-21 02:57:57

All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.In the cold storage project, the selection of cold storage is related to the overall operation of cold storage in the future. The selection of high-quality cold storage is conducive to the use and maintenance of cold storage. This requires us to inquire more about the warehouse board for cold storage engineering. Before the construction of cold storage project, we should first realize the temperature requirements of cold storage and the importance of cold storage to cold storage. Because the cold storage project has high environmental requirements such as temperature, attention should be paid to the performance and material of the cold storage board when selecting the cold storage board.BlanickThe refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. The warehouse has a wide range of temperature control. The selection, layout and wind speed field description of refrigeration equipment are suitable for the refrigeration needs of various goods. Equipped with perfect storage temperature active detection, recording and active equipment.The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production, construction and dry ceremony.Sogamoso,When outdoor air enters the cold storage body, it will not only increase the cold consumption of the cold storage, but also bring water into the warehouse. The condensation of water will lead to the building structure, especially the heat insulation structure, being damaged by moisture and freezing. Therefore, a moisture-proof and heat insulation layer should be set to keep the cold storage board building moisture-proof and air-proof performance and good sealing.Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, but it is necessary to grasp a certain limit and comprehensively consider the long-term energy consumption and initial investment, because the insulation effect of polyurethane cold storage insulation materials has a parabolic linear correlation with its bulk weight; A large number of studies have shown that the foam bulk density has better thermal insulation performance at ~ kg / cubic meter. Therefore, from centrifugal humidification to high-pressure micro fog humidification, gas-water mixed humidification, uniform humidification, no freezing and blocking, which is essentially different from other humidifiers in the market: fully closed circulation, that is, take the gas in the warehouse, return to the warehouse through the humidifier and isolate it from the outside air.


BlanickInstallation cost of fruit fresh-keeping cold storageSpecific management requirements analysis



With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?The selection of thermal insulation material is important to the quality of controlled atmosphere storage; The selection of thermal insulation materials for the controlled atmosphere storage must be adjusted to local conditions, which should not only have good thermal insulation performance, but also be economical and practical. The thermal insulation materials are divided into several types. One is the plate processed into fixed shape and specification, with fixed length, width and thickness. The plate of corresponding specification can be selected according to the installation needs of the controlled atmosphere storage. The cm thick plate is generally selected for the medium temperature controlled atmosphere storage, cm or cm thick plates are generally selected for low-temperature controlled atmosphere storage and frozen controlled atmosphere storage. The other can be sprayed with polyurethane for foaming, and the materials can be directly sprayed into the built brick or concrete warehouse. After setting, it is moisture-proof and heat-insulating. The heat-insulating material plates include polyurethane, polyphenylene grease, etc. Polyurethane does not absorb water and has good heat insulation. It is a long-term cold storage installation, installation, construction, fruit preservation and medical cold storage. Welcome to consult. But the cost is low; Polyphenylene resin has strong water absorption and poor thermal insulation but the cost is low. The structure of modern controlled atmosphere storage is developing towards assembly, and the storage components including moisture-proof layer and thermal insulation layer are made to achieve on-site assembly. The point is that the construction is convenient, fast and movable, but the cost is relatively high.There are many kinds of cold storage. According to the material,BlanickFruit and vegetable fresh-keeping cold storage installation company, it can be divided into color steel plate, stainless steel plate and salted steel. Among them,BlanickCold storage installation company, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm,BlanickLarge cold storage installation company, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.Direct material,For cold storage, but its energy consumption is very large in the use of cold storage. How can we solve this problem?Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products. - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place and do a good job in the floor and evaporator drainage system.


BlanickInstallation cost of fruit fresh-keeping cold storageSpecific management requirements analysis



Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.Management Department,The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.Balance windows shall be provided for the fabricated controlled atmosphere storage.Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.Blanick,Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms