Create entry
World Encyclopedia  > category  >  Energy Encyclopedia   

GassolHow much does it cost to install a small cold storageWorking principle and main parameters

release time: 2023-03-23 09:39:08

The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition it shall be conducive to production, construction and dry ceremony.Other aspects: in the design process of food cold storage, it is also necessary to consider the cooperation between the cold storage and on-site fire fighting, ventilation, water and electricity systems. It should meet the requirements of safety, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following points should be paid attention to during redesign and installation.Gassol,After cooling down steadily, check all parts of the refrigeration system, exhaust pressure, suction pressure and exhaust temperatureThe combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Asan, - precautions for vertical plate of cold storage: vertical plate displayThe polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.Strong deformation resistance,GassolQuotation for medical cold storage installation, not easy to crack, smooth, stable and safe. Polyurethane material has stable porosity structure and basically closed pore structure. It not only has excellent thermal insulation performance, but also has good freeze-thaw resistance and sound absorption performance. Under normal service and maintenance conditions, the life expectancy of rigid foam polyurethane insulation can reach more than years. During the structural life period, wet or electric corrosion under normal service conditions while the unit price of insect, fungus or algae foam material is higher than other traditional insulation materials, but heating will increase the cost and the cooling cost will be greatly reduced.


GassolHow much does it cost to install a small cold storageWorking principle and main parameters



How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.Scrubbers are often used in controlled atmosphere warehouses. The scrubber is more complex and requires spraying device, so it is less used. The type of air washing device to be used depends on the equipment and environmental conditions. In winter,GassolSteps for installing cold storage, the outside temperature is low, so ventilation is appropriate, while the controlled atmosphere storage and are different.More and more people begin to build cold storage, and most people choose to use cold storage for cold storage construction. Why? Why do people choose cold storage for construction? What are the advantages of cold storage? The following is a detailed introduction.Welcome calls ,Able to withstand the harsh local climate and its changes. Neither high temperature nor severe cold climate will cause irreversible damage or deformation to the external insulation system. The drastic change of the surface temperature of the external wall, such as the sudden shower after a long time of exposure, or shading during exposure, will not cause damage to the surface of the cold storage.The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring and power protection shall be provided for the box and each power branch.


GassolHow much does it cost to install a small cold storageWorking principle and main parameters



Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling,Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment, and do a good job in rain proof, moisture-proof, anti-collision, anti binding and other safety protection.As the hub of the refrigeration core, it plays the main role of repeated operation and work. After being compressed by the wholesale compressor in the fresh-keeping warehouse, the refrigerant changes from no pressure to high pressure and low pressure to a proportional pressure and low pressure. This high and low pressure can achieve the principle of refrigeration under the action of other parts.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally,GassolCold storage installation and maintenance, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.Gassol, descaling and air discharge: when there is a .mm thick oil film in the evaporator coil, in order to maintain the set temperature requirements the evaporation temperature will decrease by ℃ and the power consumption will increase by more than ; When the scale on the water pipe wall in the condenser reaches mm, the condensation temperature will rise by ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches .mpa, the power consumption will increase by about . It can be seen that it is coldThere are two kinds of refrigeration in the cold storage group: immediate refrigeration and simple refrigeration.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym