World Encyclopedia  > category  >  Machinery and industry equipment encyclopedia   

KefeldElectric cargo elevatorWhat to do if it breaks, how to fix it

release time: 2023-05-11 17:48:12

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side and the door bolt must be set on the side next to the construction electric elevator.Vertical lead screw electric lifting mechanism: Adopting a lead screw transmission method, it can achieve the lifting of a double-layer tabletop. Multiple lifting platforms can be formed as needed, and different steps can be formed within the travel range to meet the needs of meetings and performances; Pavilion, Terrace, Tower, Pavilion; Ideal props.Kefeld,Check whether the sealing of components such as the oil cylinder, oil pipe, and motor of the aluminum alloy electric elevator is good and whether there is any air leakage.The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.Le HochetAdvantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure, small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, how to fix it' >



From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machineryThe cleanliness of the hydraulic station is an important aspect of the electric elevator hydraulic station, there are relevant rules and requirements that should be referred to in the specification manual, so as to have a correct understanding and know how to achieve good cleanliness.Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.A complete range of products,According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage an intermediate stage, a T-shaped stage, or a hall.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.


KefeldElectric cargo elevatorWhat to do if it breaks, how to fix it



The list of materials for making landing doors is as follows: Table : List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.quality standard,Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.After the limit switch is activated,KefeldFixed electric elevator,KefeldSmall electric mobile elevator, only professional personnel can restore the movement of the suspension cage.Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the doorKefeld,Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.The pump body adopts an integrated pump station, all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms