WittenHydraulic unloading and tipping machineAnalysis of Causes of Blockage Failure and Discussion of Solutions

release time: 2023-11-10 16:33:14

Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Witten,The difference between home elevators and ordinary public elevators is that the focus of home elevators and ordinary public elevators is different, with some indicators significantly reduced. For example the load capacity of home elevators does not exceed kg, which is much lower than that of ordinary public elevators. Home elevators do not need to consider the issue of passenger flow, and the lifting speed is slower, ensuring safety. The lifting speed is generally between . to .m/s, and running smoothly.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Aonai jungle,Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size,WittenNew type of small elevator for household villas, door opening width, etc.), then consider the non-standard design of the elevator.


WittenHydraulic unloading and tipping machineAnalysis of Causes of Blockage Failure and Discussion of Solutions



Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.When accidentally trapped in an elevator, press the alarm bell inside the elevator, and call the elevator emergency rescue phone or community property phone for help. Do not open doors or mess with buttons, and patiently wait for rescue.The call button on each floor is no longer working, and the call is cut off.Quality Assurance,WittenHome mini elevator Small home elevator,During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed, and on the other hand, if any problems occur, someone is also responsible.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.The front room of the fire elevator is equipped with indoor fire hydrants.


WittenHydraulic unloading and tipping machineAnalysis of Causes of Blockage Failure and Discussion of Solutions



The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesOnline consultationThe front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Witten,To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment,WittenHousehold villa elevator manufacturer, and the alignment of handrail turns during continuous arrangement.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, width, and depth of the pit (if any) and observe whether there are grooves and embedded parts at the support beam.