World Encyclopedia  > category  >  Energy Encyclopedia   

KaiserslauternFabrication and installation of cold storageInsufficient environmental protection, stable and weak price operation

release time: 2023-12-14 02:02:20

Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storageIn order to maintain a constant low temperature in the cold storage, attention should be paid to the installation of cold storage panels in Guizhou: the floor, wall and flat roof of the cold storage are laid with a certain thickness of thermal insulation materials to reduce the incoming heat from the outside. In order to reduce the absorption of solar radiation, the surface of the external wall of the cold storage is painted white or light color. Therefore, cold storage building is different from general industrial and civil buildings, and has its unique structure. Cold storage buildings should prevent the entry of air and the diffusion of water vapor.Kaiserslautern,If necessary,KaiserslauternDesign and installation price of cold storage,KaiserslauternMedical cold storage, install a filter on the compressor return pipeline to prevent dirt in the system from entering the compressor and remove water in the system.The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.New Mumbai, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate, and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted, the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (mm thick) has a very large span of M and the polyurethane top storage plate (mm thick) has a span of m.Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.


KaiserslauternFabrication and installation of cold storageInsufficient environmental protection, stable and weak price operation



The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.If the relative flow changes little, there is little difference in power consumption among several regulation modes, that is the regulation mode has little impact on the energy-saving effect, or even does not save energy, but consumes more power due to the existence of the regulation device, and the variable speed regulation curve is close to the ideal curve. Therefore, the variable speed regulation mode is superior, especially the energy-saving scheme of variable frequency motor speed regulation is recommended, but the frequency conversion device needs to be added. It is recommended to actively try out the variable frequency speed regulation of small and medium capacity. Due to the high capacity and high voltage variable frequency speed regulation device, it should be combined with the specific situation and comprehensive comparison. Generally speaking, the greater the regulation depth, the more significant the energy-saving effect.How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.Direct labor,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.There are two kinds of refrigeration in the cold storage group: immediate refrigeration and simple refrigeration.At ordinary times users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.


KaiserslauternFabrication and installation of cold storageInsufficient environmental protection,KaiserslauternPrice of cold storage installation company, stable and weak price operation



Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Latest quotation, sorting room, quick freezing room, refrigeration room, channel, unloading platform, etc.Evaporation temperature the sweating temperature of the refrigeration in the wafer machine needs to be lower than the air temperature in order to transfer heat from the engine room to the refrigerant. Usually, the temperature difference of room air conditioner is between C and C. If the temperature difference cannot be maintained due to adverse factors, the operation energy consumption will increase.Able to withstand the harsh local climate and its changes. Neither high temperature nor severe cold climate will cause irreversible damage or deformation to the external insulation system. The drastic change of the surface temperature of the external wall, such as the sudden shower after a long time of exposure, or shading during exposure, will not cause damage to the surface of the cold storage.Kaiserslautern,In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.Establish a perfect computer network, make the distribution of refrigeration supply chain scientific, and achieve the traceability of food safety. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym