Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse and can bring harmful gases such as carbon oxide out of the warehouse during storage.The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, it can bear various internal and external combined loads such as wind force, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.Yingya,The refrigerator has the advantages of high cost, beautiful appearance, long service life and convenient relocation. So quickly replace spraying. The choice of spraying must have a large cold storage area, so as to reflect its cost savings.Cold storage board, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature,YingyaVegetable fresh-keeping cold storage, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage medical cold storage, quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Home,Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,After being stored in the medical cold storage project, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.These measures have achieved quite good results. Compared with several cold storages at a customer in Jining, the cold storages using their white materials have significantly lower power consumption than those using other white materials.


YingyaInstallation of small cold storageCauses of operation instability and preventive measures



Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.Expensive, high machining precision of body parts; High noise during compressor operation; Screw compressor can only be used in medium and low pressure range, not in high-pressure occasions; Due to large fuel injection and complex oil treatment system, there are many auxiliary equipment of the unit.The cold storage shall be regularly overhauled and maintained, so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.Safety production,As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling. - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.


YingyaInstallation of small cold storageCauses of operation instability and preventive measures



Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and to refrigeration compressors under Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate, and have strict requirements for temperature and humidity.Total quality managementFault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).The logistics cold storage project in the tally area belongs to the type of cold storage with frequent goods in and out and large quantity. Therefore, in order to keep the temperature fluctuation in the warehouse small, it is more necessary to store the temperature and time of goods entering and leaving the warehouse. Introduction to KFC refrigeration: logistics refrigerators with frequent incoming and outgoing goods and large throughput, especially low-temperature logistics refrigerators, and the temperature of the tally area is generally ~ ℃. In addition, a transfer room will be set in the logistics cold storage to avoid the loss of refrigeration capacity caused by frequent opening and closing of the cold storage door, or unqualified temperature and serious frosting.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.Yingya,YingyaFruit cold storage temperature,We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer it is effective to seal the hot side of the insulation layer, that is, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms