New South MemphisCold storage engineering installationWhat are the packaging methods

release time: 2022-02-24 09:46:23

For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.Judge the operating sound of the compressor, and carefully listen to the operating sound of water pump, cooling tower, compressor, fan and other equipment. In case of abnormal sound, timely warranty is required so as to avoid greater damage to the compressor due to untimely warranty.New South Memphis,New South MemphisCold storage large cold storage,The selection of thermal insulation material is important to the quality of controlled atmosphere storage; The selection of thermal insulation materials for the controlled atmosphere storage must be adjusted to local conditions, which should not only have good thermal insulation performance, but also be economical and practical. The thermal insulation materials are divided into several types. One is the plate processed into fixed shape and specification, with fixed length width and thickness. The plate of corresponding specification can be selected according to the installation needs of the controlled atmosphere storage. The cm thick plate is generally selected for the medium temperature controlled atmosphere storage, cm or cm thick plates are generally selected for low-temperature controlled atmosphere storage and frozen controlled atmosphere storage. The other can be sprayed with polyurethane for foaming, and the materials can be directly sprayed into the built brick or concrete warehouse. After setting, it is moisture-proof and heat-insulating. The heat-insulating material plates include polyurethane, polyphenylene grease, etc. Polyurethane does not absorb water and has good heat insulation. It is a long-term cold storage installation, installation,New South MemphisCold storage installation, construction,New South MemphisInstallation of low temperature cold storage, fruit preservation and medical cold storage. Welcome to consult. But the cost is low; Polyphenylene resin has strong water absorption and poor thermal insulation, but the cost is low. The structure of modern controlled atmosphere storage is developing towards assembly, and the storage components including moisture-proof layer and thermal insulation layer are made to achieve on-site assembly. The point is that the construction is convenient, fast and movable, but the cost is relatively high.A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Malanville,There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, including standard plate vertical plate width wa = mm, vertical angle plate W = mm W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables, delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?


New South MemphisCold storage engineering installationWhat are the packaging methods



The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.Degree, suction temperature, motor temperature, crankcase temperature and temperature in front of the valve, observe the frosting of the evaporator and valve, and observe the oil level and color change of the oil mirror. Whether the sound of equipment operation is abnormal.The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.Industry management, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.


New South MemphisCold storage engineering installationWhat are the packaging methods



When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Marketing Department,The cold storage shall be regularly overhauled and maintained, so as to reduce the failure rate of the refrigeration unit and achieve good refrigeration effect.Air tightness test: air tightness test of fresh storage system, also known as leak detection process, which can be divided into pressure, vacuum and ammonia filling leak detection stages.Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.New South Memphis,For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, dripping, leakage and other conditions of the water supply system exist.There are many kinds of cold storage. According to the material, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms