Create entry
World Encyclopedia  > category  >  Energy Encyclopedia   

negotiationPharmaceutical cold storage installation companyClassification and requirements of

release time: 2024-04-19 02:26:25

When installing polyurethane insulation board,negotiationCold storage engineering installation, ensure that its surface is smooth and flat without scratch and warpage.The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.negotiation,Vacuum test: after the system pressure test is qualified, the system can be vacuum leak tested. The purpose is to improve the air tightness under vacuum conditions and prepare conditions for ammonia filling of the system.Generally speaking, sealing, firmness and frost resistance.Warnes,The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage,negotiationUndertake cold storage installation, medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field, which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection, recording and active control equipment.Able to withstand the harsh local climate and its changes. Neither high temperature nor severe cold climate will cause irreversible damage or deformation to the external insulation system. The drastic change of the surface temperature of the external wall, such as the sudden shower after a long time of exposure, or shading during exposure, will not cause damage to the surface of the cold storage.


negotiationPharmaceutical cold storage installation companyClassification and requirements of



The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body,negotiationCold storage installation and maintenance, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel evenly apply two layers of foaming material on the joint surface of male and female groove, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, and the voltage should be V & plusmn; % (phase line). When the fresh-keeping warehouse equipment is not used for a long time, the main power supply of the fresh-keeping warehouse shall be cut off, and it shall be ensured that the fresh-keeping warehouse equipment is not affected by moisture, dust and other substances. The condenser on the refrigeration unit is simply contaminated, and the fresh-keeping warehouse shall be cleaned regularly according to the actual situation. To adhere to outstanding heat transfer.The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.Direct material,The importance of regular oil discharge, descaling and air discharge in the refrigeration system of the warehouse.Able to withstand the harsh local climate and its changes. Neither high temperature nor severe cold climate will cause irreversible damage or deformation to the external insulation system. The drastic change of the surface temperature of the external wall, or shading during exposure, will not cause damage to the surface of the cold storage.Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.


negotiationPharmaceutical cold storage installation companyClassification and requirements of



Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Installation material list,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.However, not all controlled atmosphere reservoirs can choose to adjust with a large depth, which still needs to be determined according to the actual needs of fans and places. We can adjust the energy-saving effect of the control fan from the production design link, coupled with the user's energy-saving effect of the hot air fan, so that the energy-saving effect of the hot air fan will be significantly improved.The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.negotiation,The service life of the cold storage depends on the quality of the refrigeration equipment, but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times, people often ignore the latter point. In daily life, we can greatly improve the service life of the cold storage and reduce the cost.Install the electric control system. The electric control system of the cold storage mainly includes electric controller, electric door, lighting and other electrical equipment in the cold storage. The power supply of the cold storage is required to be stable phase line, and the power supply or backup power supply can be used as required. The circuit shall have reasonable discharge and corresponding protective measures.Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms