Create entry
World Encyclopedia  > category  >  Building Materials Encyclopedia   

ZotmirGuide rail lifting cargo elevator liftingHow does it work?

release time: 2024-04-24 18:40:04

The surface of the brushes of each part should be kept clean, and the pressure of the brushes should be adjusted so that the area is not less than %. Professional elevator factory, large quantity favorably,ZotmirTwo ton guide rail type cargo elevator, high quality and low price. Fire-resistant-waterproof-high temperature resistant, safe and reliable.Mechanisms: Mechanisms such as tabletops, track grooves wire ropes, chains, and pulleys are made of solid materials to ensure safety.Zotmir,Improper use of oil: Inadequate maintenance of mobile lifts and other high-altitude work platform equipment will cause the fitting clearance of parts to be small, and the oil is not easy to form a uniform oil film on the friction surface. In addition, due to assembly and other reasons, it is difficult to ensure the uniformity of the fitting clearance. Thereby reducing the efficiency and causing early abnormal wear of equipment parts; in severe cases, it will cause scratches or bites on the precisely matched friction surfaces, resulting in abnormal noise of the equipment.The hydraulic lifting platform can be divided into: four-wheel mobile type, two-wheel traction type car modified type, car type, auxiliary self-propelled type, and the lifting height ranges from a meter to s meter.Victorias CityAvoid working in an environment. In the event of rain, snow and other weather, the use of the hydraulic lifting platform should be stopped to prevent the occurrence of a short circuit, resulting in electric leakage and electric shock; non-professionals are strictly prohibited from disassembling electrical appliances such as hydraulic lifting platforms. In the event of an accident, you can’t disassemble without permission to eliminate the cause. You must report to the manufacturer for repair in time, inform the phenomenon of the accident, and the manufacturer will guide you to complete the inspection or send someone to repair it; do not disassemble the appliance without permission! Professional elevator factory guarantees quality, guarantees service. Guarantees quality. Your satisfaction is our pursuit! Welcome to inquire.Conscientiously write the special construction plan for installation and construction, and make safety technical disclosures to the installers.The surface of the brushes of each part should be kept clean, and the pressure of the brushes should be adjusted so that the area is not less than %. Professional elevator factory, large quantity favorably, high quality and low price. Fire-resistant-waterproof-high temperature resistant, durable, safe and reliable.


ZotmirGuide rail lifting cargo elevator liftingHow does it work?



Safety performance: The lifting structure is made of high-strength manganese steel rectangular tube,ZotmirRail lift cargo elevator, and the scissor-type mechanical mechanism is easy to maintain, with strong stability and high carrying capacity. The maximum lifting height is about meters, and the maximum load is about tons. .Precautions for daily maintenance of hydraulic lifts Check all hydraulic pipes and joints of hydraulic lifts. The pipes must not be damaged, and all joints must be tightened.It is strictly forbidden for personnel to take the freight elevator to go up and down floors and climb.Create brilliance,Before using the aerial work platform, refer to the level beads on the equipment to judge and debug, and then proceed with the operation; the rollers and slideways confirm whether the roller slideways of the hydraulic lifting platform are dry, and if there is When drying the site, an appropriate amount of butter should be added to ensure the smoothness during operation and to avoid head-to-head wear between mechanical parts.The motor connection is wrong. When the delta connection motor is wrongly connected into a star shape, the motor still runs with full load and the current flowing through the stator winding will exceed the rated current, and even cause the motor to stop by itself. If it overheats, it will burn out. When the star-connected motor is wrongly connected into a triangle, or the motor with several coil groups connected in series to form a branch circuit is connected in parallel with two branches, it will cause the winding and core to overheat, and in severe cases, the winding will be burned.The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be careless. Moreover, from a professional point of view, there are relevant rules and requirements, and you should refer to the specification manual, scratches, small rocks on the driving tires, there may also be a peeling paint spot, and a small rust will appear after a long time. Because most of these scars are small, they are easy to ignore. Therefore, check regularly, the engine compartment cover and its surroundings, and once found, go to a professional beauty shop for processing.Quality management,The motor connection is wrong. When the delta connection motor is wrongly connected into a star shape, the motor still runs with full load, and the current flowing through the stator winding will exceed the rated current, and even cause the motor to stop by itself. If it overheats, it will burn out. When the star-connected motor is wrongly connected into a triangle, or the motor with several coil groups connected in series to form a branch circuit is connected in parallel with two branches, it will cause the winding and core to overheat, and in severe cases, the winding will be burned.When using a helmet, the helmet should be tightened and worn straight, and the strap of the helmet should be tied under the jaw and tightened.The motor winding is short-circuited. When a short-circuit fault occurs in the motor winding, the short-circuit current is much larger than the normal operating current, which increases the copper loss of the winding, causing the winding to overheat and even burn out.Zotmir,Ensure good power supply at the installation site, install a separate distribution box, and the leakage switch must meet the requirements for construction elevators when used in the distribution box. If the construction elevator installed is frequency conversion, the leakage switch should be adapted to the frequency converter when selecting the leakage switch .Ensure good power supply at the installation site, install a separate distribution box, and the leakage switch must meet the requirements for construction elevators when used in the distribution box. If the construction elevator installed is frequency conversion, the leakage switch should be adapted to the frequency converter when selecting the leakage switch .The water cooling of the hydraulic station is generally tube-type water cooling, and its type selection is based on the heat load to calculate the heat exchange area, while its air-cooled elevator is carried out by using an air cooler, and it is The heat transfer capacity is calculated according to the heat load, and then the type selection calculation is carried out under the condition that the flow rate can be satisfied. Therefore, these two kinds of cooling are not the same and there is a big difference. Long-term promotion of freight elevator factories and other, Long-term cooperation, mutual benefit and win-win. If you choose the wrong supplier, you will be overwhelmed with all kinds of after-sales troubles in the later stage. Recently, I have seen many netizens report the problem of very loud oil cylinders. Today

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms