The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, but the project cost is relatively high.Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.Kedzierzyn kozle,Ammonia filling leak test: ammonia filling leak detection can be carried out after system blowdown and pressure leak test. The purpose is to improve the air tightness of the system and lay a good foundation for the work of ammonia filling and thermal insulation materials of the system. After air leakage detection, some obvious leakage points can be found. However, due to the poor air permeability, the leakage points blocked by dirt along the tiny sand holes are not easy to be detected. Therefore ammonia must be filled. In addition to good permeability, ammonia also has odor and is easy to be found, At the same time phenolphthalein test paper can be used for leak detection because it is rose red in the presence of ammonia.Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate, cm or cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.Shahzadbur,Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, and the decline rate of warehouse temperature will also slow down.When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.Thermal insulation performance of thermal insulation materials for food cold storage the requirement of polyurethane thermal insulation materials for cold storage is thermal insulation performance, and the quality of thermal insulation performance cannot be observed before it is really put into use. It is too late to observe the difference between power consumption. In this large number of experimental tests, strict material selection is carried out in order to achieve this goal: using structural amine ether to reduce thermal conductivity and improve thermal insulation effect; Reduce the water content of various raw materials and formulas as much as possible to avoid deterioration of thermal insulation performance caused by water foaming; Polyether: the product of a large processed factory after strict postprocessing is compared with the polyether of small factory without postprocessing. The foam cell has high uniformity of foam pores and thin wall of foam holes, and its heat preservation performance is obviously better than that of ordinary foam with thick wall and big hole. The use of the tasteless amine catalyst can effectively adjust the balance between foaming and gel reaction, so that the interlayer skin of the sprayed coating is thinner, which is beneficial to the performance of the thermal insulation material of the cold storage. Ordinary polyester polyols are not used.


Kedzierzyn kozleInstallation freezer priceHow is the product surface finish grade divided



Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.Actual factors affecting the increase of exhaust temperature of fresh-keeping warehouse: low intermediate cooling efficiency, or too much scale in the intercooler of fresh-keeping warehouse affects heat exchange, the suction temperature of the later stage must be high, and the exhaust temperature will also increase. - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.Packaging strategy,It will still decrease. The humidification amount will decrease by % at degrees.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs,Kedzierzyn kozleInstallation of combined cold storage, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.


Kedzierzyn kozleInstallation freezer priceHow is the product surface finish grade divided



The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.Promotion,The efficiency of the compressor is low, the cylinder sleeve, ring and other parts are seriously worn, installation, construction, fruit preservation, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse, the temperature of the warehouse will drop slowly.Evaporator is not only an exchanger for refrigeration and bulk cooling, but also a very important one. Its task is bulk cooling. It is mainly used for refrigeration and heat absorption in fresh-keeping warehouse. In the long-term work of the fresh-keeping warehouse, the fins of the evaporator will also be covered with dirt, mostly pasted with some sundries of the products. It is specialized in products and renewable resources. Its business includes: cold storage installation, cold storage installation,Kedzierzyn kozleWhich is a good cold storage project installation, cold storage construction, fruit fresh-keeping cold storage medical cold storage. In addition, dust and other things, but reaching a certain thickness will have an impact on the cooling of the fresh-keeping warehouse, If the refrigeration of the fresh-keeping warehouse becomes poor, it should be cleaned with a special cleaning agent for the evaporator.The refrigerant charge is insufficient. At this time, just add enough refrigerant.Kedzierzyn kozle,Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.When the cold storage is used for the first time or shut down for a long time,Kedzierzyn kozleVegetable and fruit cold storage, it is strictly prohibited to stack goods in the warehouse. The warehouse must be slowly reduced to the required temperature. For the low-temperature warehouse, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse, resulting in the warehouse body.Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms