The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.There is a dedicated fire telephone in the fire elevator car.Maester,As elevator people, let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators, and dedicated cargo elevators. Dedicated cargo elevators are installed due to special needs, and we don't use many of them. Now, let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators, hold onto the elevator firmly fasten your shoelaces, and avoid getting them caught up.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Dedougou,Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, steel beams can be considered to be added between the frames for rectification.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.


MaesterStage lifting platformPipeline protection law



If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.The difference between home elevators and ordinary public elevators is that the focus of home elevators and ordinary public elevators is different, with some indicators significantly reduced. For example, the load capacity of home elevators does not exceed kg, which is much lower than that of ordinary public elevators. Home elevators do not need to consider the issue of passenger flow and the lifting speed is slower, ensuring safety. The lifting speed is generally between . to .m/s, and running smoothly.Restore the command button function in the cabin for firefighters to operate.Total quality assurance,The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction,MaesterFully electric high-altitude reclaimer, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station and automatically open the elevator door if it is in the upward direction.


MaesterStage lifting platformPipeline protection law



Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Discount,The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.Elevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch, like braking to stop.Electrical components are roughly divided into screens electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work,MaesterStage elevator, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, waterproof, high-temperature resistant, sturdy and durable, safe and reliableMaester,Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted,MaesterNew type of small elevator for household villas, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableThe compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms