LeshnoSmall installation of freezerNormalizing heat

release time: 2024-03-27 02:13:30

When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.Leshno,When installing and splicing the storeboard in the fresh-keeping storehouse, it needs to be tightly sewn to ensure the tightness; The fresh-keeping storehouse will discharge water during operation, and the drainage pipe should be installed in a place that can circulate; An anti-collision barrier shall be installed around the door of the fresh-keeping storehouse to prevent the door from being damaged by impact. To play an eye-catching role, the fresh-keeping storehouse shall be equipped with emergency lights, alarm devices and safety channels to facilitate self rescue or alarm for help in case of emergencies.The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.Fukui,The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Because polyurethane sheet has excellent thermal insulation performance, which makes people's retained items more convenient and reliable. With the continuous development of material technology, today's various cold storage materials emerge in endlessly, and the cold storage is different from each other. When purchasing we should make reasonable comparison and select products suitable for our own use needs and economic conditions.Daily maintenance and management of fruits after Warehousing: timely the temperature and humidity in the cold storage, strictly control the temperature in the cold storage, timely eliminate the bad gas in the cold storage, and adjust the temperature and humidity of the cold storage according to the different requirements of different fruits on the storage environment. If long-term drying will affect the color of the fruit, consider using a humidifier to adjust the humidity in the cold storage.Other aspects: in the design process of food cold storage, it is also necessary to consider the cooperation between the cold storage and on-site fire fighting, ventilation, water and electricity systems. It should meet the requirements of safety, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following points should be paid attention to during redesign and installation.Online consultationThe exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection, recording and active control equipment.


LeshnoSmall installation of freezerNormalizing heat



These are several very common cold storage materials. The use of these materials has greatly improved the thermal insulation and refrigeration performance of the cold storage, which makes people's retained items more convenient and reliable. With the continuous development of material technology, today's various cold storage materials emerge in endlessly, and the cold storage is different from each other. When purchasing,LeshnoInstallation of cold storage works, we should make reasonable comparison and select products suitable for our own use needs and economic conditions.Price,The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.The ground should be flat and not uneven. If the ground is uneven, the ground of the warehouse must be leveled before the cold storage can be built and installed.Generally speaking, sealing, firmness and frost resistance.Leshno,Wall and floor fixtures shall start at corners. According to the plate layout drawing, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.Floor insulation of medium-sized cold storage the structure of medium-sized cold storage is what we often call the surface, that is, the top and wall are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials,LeshnoPrice of fresh-keeping cold storage, while the ground needs to be insulated separately. At present, the common operations in the market are: laying the ground with XPS extruded board, laying moisture-proof and steam isolating SPS materials above and below the extruded board respectively, and then pouring concrete or reinforced concrete.. Maintenance of food cold storage. In a position convenient for operation outside the door of the refrigerator room, a main switch for cutting off the power supply of the refrigeration compressor shall be set. This switch shall be able to stop the operation of the refrigeration compressor, and relevant signs shall be set. If the mechanical panel is set in the main room, a button switch shall be added next to each refrigeration compressor.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms