Create entry
World Encyclopedia  > category  >  Energy Encyclopedia   

TekuchHow much is the installation of small cold storageHow to maintain 191029

release time: 2024-04-29 02:51:49

No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.Tekuch,The inlet and outlet pipe diameters of the liquid storage tank shall be subject to the exhaust and outlet pipe diameters indicated on the unit sample.General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.Sacele,Cork board: cork board can be said to be a relatively primitive kind of cold storage. The thermal conductivity of cork board is relatively low, and it is easy to obtain,TekuchMedical cold storage, so it is not difficult to process, so it is generally used as the insulation board in some ordinary cold storage. If you want to pursue better thermal insulation performance, you have to look at the following materials.Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.


TekuchHow much is the installation of small cold storageHow to maintain 191029



Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm,TekuchInstallation price of fruit and vegetable fresh-keeping cold storage, which is of great significance to the proper preservation of the cold storage.The high pressure gauge shall be installed at the opening of the liquid storage tank valve.It is required to set up a special tally room (area), and the temperature of the tally area is usually controlled at ~ + ℃.Fair price,The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage, strict testing quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then,TekuchMedical cold storage, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.In the low temperature environment, the building materials of the cold storage and the structure of each part of the cold storage should have sufficient frost resistance.


TekuchHow much is the installation of small cold storageHow to maintain 191029



The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.Product range,Install the electric control system. The electric control system of the cold storage mainly includes electric controller, electric door, lighting and other electrical equipment in the cold storage. The power supply of the cold storage is required to be stable phase line, and the power supply or backup power supply can be used as required. The circuit shall have reasonable discharge and corresponding protective measures.Whether there is a problem with the line system of the first controlled atmosphere storage. After the line problem is eliminated, check whether the cold storage is overloaded. If there is a problem with the line, please deal with it in time. When the power is overloaded the power or increase the square of the line.Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.Tekuch,For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, emitting, dripping, leakage and other conditions of the water supply system exist.During the use of cold storage, which will seriously reduce the local thermal insulation performance of the storage body.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym