PalmaAluminum alloy mast type lifting platformMaintenance

release time: 2024-04-19 20:17:57

The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Palma,The braking system of the elevator is usually closed, which means it is in the braking state when there is no power, and only when it needs to be turned on, will the power turn on the brakes. So as soon as there was a power outage, the brakes closed and the elevator was braked in mid air. When the elevator descends abnormally, cut off the power and the elevatorRestore the command button function in the cabin for firefighters to operate.Kokkola,Restore the command button function in the cabin for firefighters to operate.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.


PalmaAluminum alloy mast type lifting platformMaintenance



The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.Elevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch, which can trigger the elevator to shut down in case of any abnormality. The elevator getting stuck is actually when the system detects an abnormal signal and triggers a protective device, like braking to stop.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft,The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.


PalmaAluminum alloy mast type lifting platformMaintenance



The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Statistics,Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed,PalmaDuplex villas stacked with household elevators, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications,PalmaHousehold sightseeing elevator, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified,PalmaFixed lifting stage, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Palma,The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyTower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms