Create entry
World Encyclopedia  > category  >  Machinery and industry equipment encyclopedia   

CasoriaAkloThe chemical nature of the reaction

release time: 2024-04-19 21:40:54

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.Use floor doors and cage door devices on construction sites where conditions permit.Casoria,Precautions for safe use of electric elevators: Before use, remove any obstacles or debris near the electric elevator that may hinder operation, and check whether the operating handle can be used normally.Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor positionSaynshand,Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than .m; If the rated speed is not greater than .m/s, the safety distance can be .m.Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination,CasoriaSan Antonio, shallow foundation pit required, large stroke stable operation, low noise, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.


CasoriaAkloThe chemical nature of the reaction



It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easierWhen adding hydraulic oil, we can extend the oil cylinder to the high position for filling. When filling,CasoriaChengde, the lifting platform should not exceed the high position, and then retract the oil cylinder back to the low position to check if the hydraulic oil level is lower than the low position, and maintain it between the two.The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator,When applying a normal force of N to any position on either side of the door using a rigid mm square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding mm; After the test, it worked normally.During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed mm.The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.


CasoriaAkloThe chemical nature of the reaction



Setting requirements: For construction electric elevators that operate in multiple shifts,CasoriaToulouse, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.demand,Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.The counterweight steel wire rope should be equipped with an anti loosening device that is sensitive and reliable.Principle of electric elevator rotary valve: When the electric elevator rises, the rotary valve will automatically open. To close the plug valve, it is necessary to first turn the handle to turn the plug to a degree position until it is closed, and then turn the transmission handwheel to lower the plug and achieve sealing.Casoria,The use of standard section connecting bolts should comply with the user manual and specification requirements.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

If you think this entry needs to be improved, please edit

Previous OstrovinkaFoot hydraulic lifting platform vehicleOverall market volume    Next VillebanHydraulic lifting platformmarket