Create entry
World Encyclopedia  > category  >  Energy Encyclopedia   

BalchikCold storage installationDirect material

release time: 2023-02-05 05:37:03

Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.Balchik,Air tightness test: air tightness test of fresh storage system, also known as leak detection process, which can be divided into pressure, vacuum and ammonia filling leak detection stages.Install the temporary lighting facilities in the warehouse install and arrange the construction electrical equipment, and do a good job in rain proof, moisture-proof, anti-collision anti binding and other safety protection.Bykhaw,Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.During the use of cold storage, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate, which will seriously reduce the local thermal insulation performance of the storage body.The efficiency of the compressor is low, and the refrigerating capacity can not meet the load requirements of the warehouse: due to the long-term operation of the compressor, the cylinder sleeve, ring and other parts are seriously worn, the long-term cold storage installation, installation, construction, fruit preservation,BalchikCold storage transfer, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced, and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse, the temperature of the warehouse will drop slowly.


BalchikCold storage installationDirect material



Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.During the use of controlled atmosphere storage, it must be maintained on time and scientifically. No matter how good the equipment is, without scientific use and maintenance, its service life and effect will be discounted.When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Analysis project,Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed small heat conduction temperature difference and simple system software, so it is widely used.There are many kinds of cold storage. According to the material, color steel plate has strong anti rust ability stainless steel plate and salted steel. Among them, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, including standard plate vertical plate width wa = mm, W = mm W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.


BalchikCold storage installationDirect material



Cold storage board, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation,BalchikVegetable fresh storage company, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Scheme customization,Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking, every ℃ increase in the evaporation temperature of the cold storage can save energy by ~ . Therefore, on the premise of meeting the refrigeration process of the product, the liquid supply can be adjusted to increase the evaporation temperature as much as possible.The circuit system must be -wire system. If there is no ground wire, the ground wire shall be added.There should be excellent drainage pipe standard around the warehouse, the soil temperature should be low, there should be interlayer under the cold storage, and maintain good natural ventilation. Maintaining dryness is very important for the cold storage. In addition, before the construction of the cold storage, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built.Balchik,The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane board has very good thermal insulation performance and does not absorb moisture.Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, small heat conduction temperature difference and simple system software, so it is widely used.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms