BurgasVertical hydraulic elevatorRestrictive factors during use

release time: 2024-04-23 06:05:39

it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform and other parameters.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).Burgas,Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Turkmenabat,If the elevator is already on the first floor immediately open the elevator door and enter the firefighter's dedicated state.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment and the alignment of handrail turns during continuous arrangement.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.


BurgasVertical hydraulic elevatorRestrictive factors during use



Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Slide elevators are installed inside buildings and are often used parallel to buildings and sidewalksThe effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Customer first,Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, the elevator happens to run up or down to this point, and the hall door is shorted,BurgasElevating platform stage, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, waterproof with a large quantity and excellent quality at a reasonable price. It is fire-resistant, high-temperature resistant, sturdy and durable, safe and reliableThere is a dedicated fire telephone in the fire elevator car.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.


BurgasVertical hydraulic elevatorRestrictive factors during use



The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.Inspection standard,To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.Elevators are used to transport firefighters, passengers, and fire-fighting equipment in the event of a fire. They are used to transport frozen goods in large cold storage or refrigeration workshops. However, they need to meet the requirements of sealing the door leaves and guide rails at the moving parts. Professional household elevators, villa household elevators, household elevator manufacturers, and small household elevators have stable, safe, reliable, and maintenance free performance, and their technical level has reached the domestic level, Meet the advanced level of international similar products and immersion requirementsMeasurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the site has not yet been constructed, is under construction,BurgasStage curtain elevator, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Burgas,b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.In the event of a fire,BurgasHome elevator villa self built house, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.


Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms