SalonikiInstallation of refrigeration equipment in cold storagePrinciple of correct working direction

release time: 2023-06-05 02:24:45

The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.Saloniki,A new way.However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.Omdurman,Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time must be strictly within minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes.Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor, and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.


SalonikiInstallation of refrigeration equipment in cold storagePrinciple of correct working direction



Other aspects: in the design process of food cold storage, ventilation, water and electricity systems. It should meet the requirements of safety, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following points should be paid attention to during redesign and installation.The installation of refrigeration pipeline requires that the diameter of copper pipe shall be selected in strict accordance with the interface of compressor suction and exhaust valve. When the separation between condenser and compressor exceeds M, the pipeline diameter shall be increased.Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.Where to sell API,The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following points: a low-temperature hall, a closed platform, an anti-collision flexible seal, and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.Emergency measures during the use of the medical cold storage project, it may also encounter power failure or power failure. In fact most medical cold storage projects will be equipped with emergency equipment, the cold storage door should be closed in time, So as not to expose more air conditioners,SalonikiCold storage installation, resulting in corresponding problems in the quality of stored products. The medical cold storage project also has a self rescue system in time. If the temperature of the cold storage exceeds the limit the system cooling system will also be turned on. When the temperature returns to normal, it will be automatically turned off.


SalonikiInstallation of refrigeration equipment in cold storagePrinciple of correct working direction



It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even in the work, the water temperature is lowanalysis,In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage, you should install it from the corner first. Later,SalonikiThat's good, according to the height of the cold storage, make a hole in the middle of the insulation board, and tighten the angle iron parts until there is a hole on the insulation boardAfter years of service, the refrigeration oil inside the compressor should be replaced. The oil, copper, iron and impurities caused by wear are mixed in the refrigeration system, which thickens the refrigeration oil, deteriorates the fluidity and performance, reduces the effect, takes a long time, increases the burden on the compressor, and the current will increase relatively compared with the new machine, which is a bad phenomenon.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.Saloniki, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.The wide, light and thin walls are made of rigid polyurethane foam at the same time as structural materials, making the whole structure have the advantages of light weight, large span and high load. The thinner polyurethane sandwich plate can meet the relevant provisions on building energy consumption limit, which allows the use of thinner plates during construction and saves building space.Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications and corresponding protection measures shall be taken for the installed equipment.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms