the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate

During the installation of polystyrene storehouse, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.New zamki in the quick freezing warehouse,Regularly maintain whether the connecting pipes on the connecting pipes and valves of the refrigeration unit are firm and whether there is refrigerant leakage. The way of leak detection is to use sponge or thin cloth with detergent foam, and then evenly coated in the area to be leaked,New zamkiHow much is the design and installation of cold storage, and observe for a few minutes. If water leaks, and then tighten or gas cut it.When using the cold storage, try to keep the ground clean and professional cold storage installation,Toyama-shi,Judge the operating sound of the compressor, and carefully listen to the operating sound of water pump, compressor,New zamkiInstallation price of cold storage, fan and other equipment. In case of abnormal sound timely warranty is required, so as to avoid greater damage to the compressor due to untimely warranty.The refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan, which can be ceiling type. If the number of warehouses is small and the volume does not exceed cubic meters, the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses the mode of multiple heads in parallel can be considered.Cork board: cork board can be said to be a relatively primitive kind of cold storage. The thermal conductivity of cork board is relatively low, and it is easy to obtain, so it is not difficult to process, so it is generally used as the insulation board in some ordinary cold storage. If you want to pursue better thermal insulation performance, you have to look at the following materials.


New zamkiInstallation price of fresh-keeping cold storageSubstantial damage to the industry



For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.The air conditioning warehouse is equipped with standby power supply. After eliminating the line and load problems, it is the maintenance of external irresistible power lines. If the refrigerated goods in the air conditioning warehouse are expensive or vulnerable to temperature changes, it can be considered to equip the air conditioning warehouse with standby power supply to ensure the operation of refrigeration equipment in the cold storage in a short time after power failure. Large air conditioning warehouses can be considered to be equipped with generator sets, Automatically switch the generator set for power generation after power failure for use. For example, dual mains power can be used.Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.Installation material list,The three-dimensional automatic cold storage adopts a computer, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.Because polyurethane sheet has excellent thermal insulation performance, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)


New zamkiInstallation price of fresh-keeping cold storageSubstantial damage to the industry



Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.Process inspection,The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment, transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present, the vast majority of cold storage use polyurethane insulation board. What are the characteristics and advantages of polyurethane insulation board?The volume of cold storage the size of cold storage shall be calculated according to the volume occupied by the stacking of goods stored in the cold storage, the indoor space between the stack and the wall, and the gap between the ceiling and the packaging room. After determining the volume, the length width ratio of the cold storage shall be determined. When designing the cold storage, necessary auxiliary engineering buildings and equipment should also be considered, such as working intermediate, packaging and combing room, special tool warehouse and loading and unloading platform, so as to ensure the quality of the cold storage.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.New zamki,The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications, cold storage installation, cold storage construction,New zamkiInstallation diagram of cold storage door, fruit preservation cold storage, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and then refer to the following specifications.There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.