XingtaiLiaoningWhat are the production precautions for

release time: 2024-04-27 11:54:09

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator with a size of meters by meters.The hydraulic oil forms a certain pressure by the vane pump, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).Xingtai,Aluminum alloy lifting platforms can be divided into single column aluminum alloy, cargo elevator, double column aluminum alloy, three column and four column aluminum alloy. Can be used in factories automated warehouses, parking lots, municipal facilities, docks, and installationsThe entrance of each landing platform must be equipped with a landing door,XingtaiPoitiers, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.buffalo,Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required, large stroke, stable operation, low noise, accurate positioning,XingtaiZaenstad, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.The bearing capacity of the ground under the concrete foundation plate should be greater than .Mpa.


XingtaiLiaoningWhat are the production precautions for



It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easierIn addition, when adding hydraulic oil, it is necessary to ensure the quality of the hydraulic oil, as some hydraulic oil manufacturers will choose hydraulic oil with poor quality. Hydraulic oil such as hydraulic lifting platforms not only cannot have any effect on folding arm elevators, but also affects the working efficiency of folding arm electric elevators due to deterioration issues.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed mm.Customer first,Implementing multiple shifts of homework should fill in and submit records according to regulations.When the foundation is set on the roof or floor structure,XingtaiPesaro, the bearing capacity of its supporting structure should be checked.The foundation base or embedded parts should be fully embedded in the concrete foundation plate.


XingtaiLiaoningWhat are the production precautions for



Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.Inspection requirements,The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than .m; If the rated speed is not greater than .m/s, the safety distance can be .m.Construction electric elevators must be equipped with lifting cages and reusable buffers, and comply with regulatory requirements.There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least . meters.XingtaiThe wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms