Old horsePharmaceutical company cold storagemarket price

release time: 2023-05-15 12:52:24

Moreover, polyurethane does not produce harmful gas at high temperature.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.Old horse,Conduit installation shall be beautiful and firm.Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator, the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.Dubrovnik,When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time must be strictly within minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes. - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.


Old horsePharmaceutical company cold storagemarket price



Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use,Old horseCold storage, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.Regularly maintain whether the connecting pipes on the connecting pipes and valves of the refrigeration unit are firm and whether there is refrigerant leakage. The way of leak detection is to use sponge or thin cloth with detergent, foam, and then evenly coated in the area to be leaked, and observe for a few minutes. If water leaks, and then tighten or gas cut it.The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.knowledge,Establish a perfect computer network make the distribution of refrigeration supply chain scientific, and achieve the traceability of food safety. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However, at present,Old horseInstall fruit preservation cold storage, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.


Old horsePharmaceutical company cold storagemarket price



Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Old horseHow much is it to install a small cold storage,Discount,General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.Due to the slow cooling, all equipment will consume electric energy during operation. If the cooling is slow, the equipment will stop and cannot consume electricity, so the electricity charge will not be consumed. As a high energy consuming equipment, the daily power consumption of cold storage is relatively large. If the refrigeration effect is not good, the annual use cost will directly double several times. Moreover, if the equipment operates for a long time, the service life will be reduced accordingly, which is something users don't want to see.During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Old horseFeatures of quick freezing warehouse: the quick freezing technology is advanced, the frost free quick freezing method is adopted, and the automatic frost is adopted. The method can only be used by microcomputer. The refrigeration system adopts green refrigerant, which belongs to the international advanced refrigeration technology in the st century.General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms