Create entry
World Encyclopedia  > category  >  Energy Encyclopedia   

SalonikiInstallation of refrigeration equipment in cold storageNew trade model of governance

release time: 2023-12-15 03:10:54

When installing the polyurethane insulation board, the adhesion between the panel of the polyurethane insulation board and the thermal insulation material is short and often high.Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know,SalonikiHow much does it cost to install a cold storage, the cold storage has great requirements for the thermal insulation effect of building materials. If the thermal insulation effect of building materials is not good, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next, let's understand the physical properties of polyurethane insulation board.Saloniki,The tightness of water valve and brine valve, the flexibility of valve, and disassembly and cleaning if necessary.The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present, most cold storages are constructed with single-layer steel structure, and are equipped with combined thermal insulation storage body, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.Inda Silase,The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition it shall be conducive to production, construction and dry ceremony.


SalonikiInstallation of refrigeration equipment in cold storageNew trade model of governance



The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, the air-conditioning fresh-keeping warehouse in the machine room can automatically and accurately adjust the operation of the equipment, so as to maintain the required refrigeration conditions and improve the economy of the operation of the fresh-keeping warehouse.Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.Quality inspection report,When the cold storage is built, the diffusion of water vapor and the infiltration of air shall be prevented. When outdoor air invades, it will not only increase the cold consumption of the cold storage, but also bring moisture into the warehouse. Moisture condensation will damp the heat insulation structure and freeze and damage the cold storage structure. Therefore, it is necessary to set moisture-proof and heat insulation layer, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other products, which have a complete variety sell well at home and abroad,SalonikiInstall cold storage door, and have a long service life! Products lead the wire industry. Welcome to inquire, so that the cold storage building has good sealing, moisture-proof and steam isolation performance.The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.Install the electric control system. The electric control system of the cold storage mainly includes electric controller, electric door, lighting and other electrical equipment in the cold storage. The power supply of the cold storage is required to be stable phase line, and the power supply or backup power supply can be used as required. The circuit shall have reasonable discharge and corresponding protective measures.


SalonikiInstallation of refrigeration equipment in cold storageNew trade model of governance



The overall construction achievements of the cold storage project have been put into use, and the service life can reach years.Sampling inspection,Where do you need to build the refrigerator, the size of the refrigerator or the storage capacity (size, storage capacity, ton, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger, you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors,SalonikiMedicine frozen warehouse, refrigeration units, industrial cooling fans / pipe slots thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.For those large-scale fresh-keeping warehouse wholesalers, if the equipment fails due to long-term neglect of maintenance, construction of cold storage we should do a good job in the maintenance of fresh-keeping warehouse wholesalers in the process of daily use.Installation of cold storage fruit preservation cold storage and medical cold storage have stable, safe, reliable and maintenance free performance. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, it must be cleaned in time, and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.Saloniki,What should be considered in building a cold storage? In these aspects, food cold storage is a systematic project of artificial refrigeration to ensure food quality and reduce food decay in a low-temperature environment. Refrigeration technology affects the design of food cold storage, meets the needs of refrigeration technology convenient production, energy saving and cost reduction. What problems should be considered in the construction of food cold storage?The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.

Attachment list


0

The content of the entry is for reference only. If you need to solve a specific problem (especially in the fields of law, medicine, etc.), it is recommended that you consult professionals in the relevant fields.

Synonym

No synonyms